Default Setting
1000 milliseconds
Command Mode
Interface Config
9.3.2.3 ipv6 mld last-member-query-interval
Use this command to set the last member query interval for the MLD interface, which is the value of the
maximum response time parameter in the group specific queries sent out of this interface. The range for
<last-member-query-interval> is 0 to 65535 milliseconds.
Syntax
ipv6 mld last-member-query-interval <1-65535>
no ipv6 mld last-member-query-interval
no - Use this command to reset the <last-member-query-interval> parameter of the interface to the
default value.
Default Setting
1000 milliseconds
Command Mode
Interface Config
9.3.2.4 ipv6 mld last-member-query- count
Use this command to set the number of listener-specific queries sent before the router assumes that
there are no local members on the interface. The range for <last-member-query-count> is 1 to 20.
Syntax
ipv6 mld last-member-query-count <1-20>
no ipv6 mld last-member-query-count
no - Use this command to reset the <last-member-query-count> parameter of the interface to the
default value.
Default Setting
2
Command Mode
Interface Config